How to turn on the Atlant refrigerator: complete instructions

After purchasing new equipment or transporting it to a new place of residence, the owner is faced with the primary question of how to properly start the unit. Errors during the initial activation stage can lead to serious compressor damage or reduced cooling system life. Refrigerators Atlant are famous for their reliability, but they, like any complex equipment, require compliance with certain time intervals and procedures.

Many users rush to immediately load products and set the maximum power, which is a gross technical error. Oil stabilization in the compressor and equalizing the temperature of internal components is a process that cannot be forced. In this article, we will analyze in detail the algorithm of actions that will allow your device to reach operating mode without unnecessary loads and the risk of failure.

Following simple preparation rules will ensure long and silent operation of the equipment for many years. Let's look at why wait time is so important and what steps you need to take before pressing the power button.

Importance of wait time after transport

Transporting a refrigerator, especially in a horizontal position or at a strong tilt, causes movement compressor oil from the engine crankcase into the refrigerant circuit. If you turn on the unit immediately, the oil that has not had time to drain back can create a water hammer or clog the capillary tube. This will cause the compressor to work with overload, trying to push the refrigerant, which is fraught with its combustion.

The time required for settling directly depends on the transportation conditions and the ambient temperature. In the summer, when the oil is more liquid, the drainage process occurs faster, but in winter, at low temperatures, the viscosity of the lubricating fluid increases and it takes longer to return to the crankcase.

⚠️ Attention: If the refrigerator was delivered in frosty weather, it is strictly forbidden to plug it into the network immediately after bringing it into a warm room. A sharp temperature change will cause the formation of condensation on the electrical contacts, which can lead to a short circuit.

Recommended time intervals for settling equipment Atlant vary depending on the situation:

  • ⏳ For vertical transportation without a strong tilt, 2-4 hours are enough.
  • 🚚 After horizontal transportation, a wait of 8 to 12 hours is required.
  • ❄️ If the equipment is brought in from the cold, the wait should be at least 24 hours before turning it on.
📊 How did you transport the refrigerator?
Vertical in the back
Lying in a passenger car
In a special van
Did not transport, new from the store

Ignoring This time frame is the most common reason for calls to service centers in the first months of operation. The compressor is the heart of the refrigerator, and replacing it is an expensive procedure that can easily be avoided by simply waiting.

Primary preparation and installation of equipment

Before you think about it about the power supply, it is necessary to ensure the correct conditions for the operation of the device. The refrigerator Atlant requires installation on a flat, hard surface. Misalignment of the housing can lead to loose fitting of the doors, disruption of refrigerant circulation and increased noise during operation of vibration mechanisms.

Use a building level to check the horizontal level of the installation. Height adjustment is carried out by rotating the front support legs. This action is critically important, since modern models often have an automatic door closing mechanism, which only works at a certain angle of tilt of the body back.

Particular attention should be paid to the ventilation system. The back wall of the refrigerator, where the condenser is located (black grille), should be at least 5-7 centimeters from the wall. Impaired heat dissipation will lead to overheating of the compressor and increased energy consumption.

⚠️ Attention: Do not install the refrigerator near heaters, stoves, or in direct sunlight. This will create an additional thermal load, forcing the compressor to work almost without stopping.

For the convenience of checking distances and gaps, you can use the following table of recommended installation parameters:

Parameter Minimum value Optimal value Consequences of violation
Distance to wall 5 cm 10 cm Condenser overheating
Gap sides 2 cm 5 cm Difficulty opening doors
Distance to stove 30 cm 50 cm Deformation of seals
Height of legs Adjustable The front ones are higher than the rear ones Spontaneous opening

After installation, make sure that the transport locks, if they were inside the cells, completely removed. Internal shelves and drawers must be installed in their regular places according to the instructions.

The process of first connection to the network

When the settling time is up and the equipment is installed, you can proceed to the most crucial moment - the first connection. Make sure that the outlet to which the refrigerator will be connected meets safety requirements. Grounding is a prerequisite for preventing electric shock and correct operation of electronics.

It is not recommended to use an extension cord or tee, especially if they have poor quality contacts. The ideal option is a separate outlet located in close proximity. If a surge protector is used, it must be designed for currents of at least 10 Amps.

Insert the plug into the socket tightly until it stops. In models Atlant with electronically controlled dispensing, the display or indicators will immediately light up, signaling the supply of power. In mechanical models, you will hear a characteristic click and start of the compressor, which may be accompanied by a slight hum.

☑️ Initial startup

Completed: 0 / 1

In the first minutes of operation, listen to the sounds made by the unit. A slight gurgling or hissing sound is allowed - this is the refrigerant moving normally through the pipes. However, there should be no extraneous knocking, grinding or loud vibrations.

Why is a new refrigerator humming?

The humming may be caused by the fact that the internal parts have not yet gotten used to each other. Also, the noise level depends on the levelness of the installation. If the humming does not go away after 2-3 days, check whether the condenser tubes are touching the cabinet wall or each other.

Setting the temperature mode

Immediately after switching on, do not set extremely low temperatures. Allow the system to smoothly return to operating mode. In refrigerators Atlant with mechanical control, the thermostat usually has a scale from 1 to 7 (or from Min to Max). For the first start, it is optimal to set the regulator to the middle position - usually this is the number 3 or 4.

In models with electronic control, the setting is made through the panel on the door. Here you can set the exact temperature in degrees Celsius. Standard values ​​for normal operation: +4°C for the refrigerator compartment and -18°C for the freezer.

Do not load the chamber with products immediately. An empty refrigerator will reach temperature faster and more evenly. The primary cooling process can take from 2 to 6 hours depending on the volume of the chambers and the room temperature.

⚠️ Attention: If after 3-4 hours of operation the walls inside the chamber remain warm and the compressor does not turn off, there may be a refrigerant leak or a malfunction of the thermostat. In this case, operation should be stopped.

You can control the temperature using an external thermometer placed in a glass of water on the middle shelf. This will give a more accurate result than the readings of the built-in sensor, which may have an error.

Loading products and entering the mode

You can load products into the refrigerator compartment only after it has cooled to the set temperature. Suddenly placing a large volume of warm food will cause the compressor to wear out, which is unacceptable for a new unit.

Distribute the food evenly without closing the ventilation holes inside the chamber. Circulating cool air is key to maintaining the same temperature in all areas. Products should not fit tightly to the back wall, so as not to freeze to it.

You should also not put food in the freezer to freeze in the first hour. Let it gain temperature -18°C and turn off at least once. For quick freezing, models Atlant have a function Super Freezethat is activated several hours before loading a large volume of products.

Check the operation of the No Frost system (if your model has it). Make sure that an ice crust does not form on the products or walls in the chamber during the first day of operation.

Diagnostics of possible problems during startup

Even if all the rules are followed, situations may arise that require attention. If the refrigerator turned on, but after a while it turned off and does not start again, check the voltage in the network. Voltage surges can activate the protective relay.

Continuous operation of the compressor without shutting down during the first day is normal if the chamber is warm. But if it hums for more than 24 hours and does not cool, this is a sign of a malfunction. It is also worth paying attention to the heating of the side walls - they can be warm, since the defrost circuits pass there, but they should not be hot.

Frequent user mistakes when starting up for the first time:

  • ❌ Switching on ahead of time (oil is not glass).
  • ❌ Setting maximum cold immediately (overload).
  • ❌ Loading with warm products (cycle violation).
  • ❌ Ignoring the installation level (noise and distortion).
What to do if there is a plastic smell?

A slight technical smell in the first hours of operation is acceptable - it is burning out preservatives on heating elements. If the smell is strong and does not go away after a day, turn off the device and contact service.

Frequently asked questions (FAQ)

How long exactly should the Atlant refrigerator sit?

The settling time depends on the conditions of transportation. In summer, with vertical transportation, 2-3 hours is enough. In winter or after transportation lying down, you need to wait at least 8-12 hours, or better yet a day, so that the oil is completely returned to the compressor.

Can the refrigerator be plugged into an extension cord?

Manufacturers do not recommend using extension cords, as they can cause poor contact and fire. If you cannot do without them, use only high-quality surge protectors with grounding, designed for a power of more than 2 kW.

Why does the Atlant refrigerator hum loudly after turning on?

The new compressor may work louder due to parts that have not yet been worn in. Also check that the refrigerator is level and not touching a wall or furniture. If the noise does not subside after a week, diagnostics are required.

Do you need to wash the inside of the refrigerator before using it for the first time?

Yes, definitely. Wipe the interior surfaces with a damp cloth and a solution of baking soda or a mild detergent to remove industrial dust and the smell of new plastic. Let the cameras dry before turning them on.