Situations, when owners need to isolate the freezer compartment in the refrigerator Atlantoccur quite often, especially during the harvest period or when moving. Many users mistakenly believe that it is enough to simply set the regulator to zero, but in two-compressor models this process has its own technical nuances. Understanding the operating principle of your unit will help you avoid food spoilage and incorrect operation of electronics.
Modern refrigerators Atlant are often equipped with a control system that allows you to independently regulate the temperature in different compartments. However, if we are talking about older models or specific operating modes, the user needs to know the exact sequence of actions. Incorrect handling of the regulators can lead to defrosting of the contents of the freezer while the main compartment is running or, conversely, to excessive energy consumption.
In this material we will analyze in detail the shutdown algorithms for various types of compressors, explain the purpose of the indicators and consider the fast freezing modes. It is important to take into account that the design features of models of series KSh-268, KHM-2808 and newer lines may differ significantly. Let's figure out how to properly control the climate inside your refrigerator.
Design features of Atlant refrigerators
The fundamental difference that determines the method of temperature control is the number of installed compressors. In single-compressor models, the refrigerant circulates through a single circuit, cooling both compartments simultaneously. In such cases, it is technically impossible to completely “turn off” the freezer while leaving the refrigerator running without disrupting the unit’s operating cycles.
Two-compressor systems, which are widely represented in the model range Atlant, allow you to control the climate in each chamber independently. This means that you can set the freezer control to "0" or "Off" while the refrigerator compartment continues to operate as normal. It is the presence of two independent circuits that gives the user flexibility in settings.
It is also worth considering the type of control: mechanical or electronic. In mechanics, adjustment is made by turning the thermostat handle, which is a reliable and time-tested solution. Electronic control, often found in models with a display on the door, requires configuration through the control panel and may have its own software limitations.
⚠️ Attention: Before starting any manipulations with the controls, make sure that the refrigerator is connected to the network and is in working order to avoid display errors.
Understanding what type of cooling system is installed in your device is the first step to competent operation. If you are not sure about the number of compressors, look at the technical data sheet or inspect the back wall of the unit - there are usually one or two motors located there.
Control in models with one compressor
Owners of single-compressor models Atlant it is important to know that isolated shutdown of the freezer compartment is not provided for by design. The refrigerant passes through the freezer evaporator and then through the refrigerator compartment evaporator. An attempt to turn off one of the circuits will lead to disruption of freon circulation.
In such units, there is usually only one temperature controller, and it controls the operation of the compressor as a whole. If you turn the knob to the minimum position, the temperature will drop in all chambers. If you turn off the refrigerator completely, the entire contents will defrost. The only way to “turn off” the freezer here is to completely defrost the device.
There are models with the so-called “crying evaporator” system in the refrigerator compartment and static cooling in the freezer compartment. Even in this case, with one motor, it will not be possible to separate their work programmatically or mechanically through standard regulators. The compressor either pumps freon or stands still.
Why can’t a single-compressor refrigerator be converted?
To separate the circuits, it would be necessary to install an additional solenoid valve, a second thermostat and change the connection diagram, which is not economically feasible and voids the warranty.
If your goal is to store vegetables in the main compartment without deep freezing products, in single-compressor models you will have to put up with a working freezer. An alternative is to use the minimum power mode, if the design of the thermostat allows such a setting, but this will only reduce the cooling intensity and not stop it.
Instructions for two-compressor models
Happy owners of two-compressor refrigerators Atlant have complete freedom of action. To turn off the freezer in such models, you need to find a separate regulator, which is usually located next to the refrigerator compartment regulator. They are often marked with numbers from 1 to 7 or have a scale from Min to Max.
To turn off the freezer, you need to turn the corresponding knob counterclockwise until it stops. On the scale, this position is usually indicated by a number 0 or an inscription OFF. At this point, the freezer compressor stops receiving a signal to start, and the temperature inside begins to gradually increase.
This is normal for mechanical thermostats - they require time to cool or heat the sensitive element. After 10-15 minutes, the motor operation should stop, as evidenced by silence and absence of vibration.
☑️ Algorithm for turning off the freezer
If your model has electronic control, the procedure may vary. In some cases, you need to hold down a certain combination of buttons or use a long press on the snowflake symbol. In such situations, it is better to refer to the instructions, since software from different years of release may have differences in the operating logic.
Super Freeze modes and their influence
Many users confuse completely turning off the camera with the super freezing mode. The function Super Freeze (Super Freeze) is designed to quickly lower the temperature to minimum values, which is useful when loading a large amount of fresh food. Activating this mode causes the compressor to work continuously, ignoring the thermostat readings.
In models Atlant with electronic control, this mode is often activated by a button with a snowflake or the inscription "Super". In mechanical models, a separate button or position of the regulator is responsible for this. It is important to understand that turning Super Freeze on is the opposite of turning it off. The camera does not turn off, but works at its maximum capacity.
Sometimes the super-freeze mode has a shutdown timer. For example, it can work automatically for 24-48 hours, after which the refrigerator itself will return to the set parameters. If you accidentally activated this function and cannot “turn off” the freezer, check whether the active freezing indicator is on.
To turn off the super freeze mode, you must press the same button again or wait until the time has elapsed automatic shutdown. After this, the regulators will again control the temperature as normal. If the indicator continues to light after a day, there may be a failure in the electronic module.
Indication and signals on the control panel
Modern refrigerators Atlant are equipped with an informative display panel that helps the user monitor the status of the device. When the freezer is turned off or the temperature is violated, a red indicator lights up, often in the shape of an exclamation mark or a flashing snowflake.
If you turned off the freezer manually (turned the regulator to 0), the red temperature indicator coming on is a normal reaction of the system. It signals that the temperature inside the chamber is higher than normal. In dual-compressor models, this indicator may relate specifically to the freezer compartment.
A green indicator, on the contrary, usually indicates normal operation and the set temperature has been reached. The presence of a yellow indicator often indicates that the super freeze mode is turned on. Understanding the color coding allows you to quickly diagnose the condition of the unit without unnecessary measurements.
| Indicator color | Value | User action |
|---|---|---|
| Green | Normal operation | No action required |
| Red (flashing) | Temperature above normal | Check the door is closed or settings |
| Red (lit) | Temperature not reached | Wait for cooling or check the regulator |
| Yellow | Super freezing mode | Disable if the mode is not needed |
Wait Please note that in some models, when the power is completely turned off or the regulator is set to zero, the indication may go out completely. This means that the electronic module also goes into sleep mode or is disconnected from camera control. In such cases, you should only focus on the position of the mechanical handles.
Store mode and long-term absence
If your question “how to turn off the freezer” is related to a planned departure for a long period, then in refrigerators Atlant a special mode, often designated as “Store” or “Vacation,” can be useful. However, there is an important nuance here: this mode is usually designed to save energy in the refrigerator compartment, leaving the freezer working.
In the "Store" mode, the temperature in the main chamber rises to +10..+15°C, which prevents the appearance of mold and odors when the refrigerator is empty, but allows you to keep frozen food in the freezer. The freezer compressor continues to operate normally. Therefore, if your goal is to turn off the freezer, the “Vacation” mode will not suit you.
To completely turn off the appliance before a long absence, it is recommended not just unscrew the controls, but unplug the cord from the socket. After this, the doors of both compartments must be left ajar. This will prevent the formation of a musty smell and the proliferation of bacteria inside the sealed space.
⚠️ Attention: It is strictly forbidden to leave the refrigerator on with the doors open - this will lead to the compressor burning out due to continuous operation.
If you need to leave only the freezer on (for example, for storing meat), and turn off the refrigeration compartment, then in two-compressor models Atlant this is feasible. You simply set the refrigerator compartment regulator to 0, and leave the freezer in the working position. Single-compressor models do not have this function.
Frequently asked questions (FAQ)
Is it possible to turn off the freezer in a single-compressor Atlanta by sealing the damper?
Theoretically, overlap Using a cold air duct may lower the temperature in the freezer, but this will disrupt the operation of the refrigerator compartment and may lead to compressor failure due to changes in system pressure. Structurally, this is not provided for and is a risky modification.
Why does the red light light up after the freezer is turned off?
The red indicator lights up when the temperature inside the chamber exceeds a safe threshold (usually above -12..-15°C). When the regulator is turned off to zero, the temperature naturally rises, so the lighting of the lamp is a normal reaction of the sensor, indicating that the food can defrost.
How long does it take for the freezer to defrost after turning off?
The defrosting time depends on the amount of food, the temperature in the room and the thickness of the ice layer. On average, with a full load and the compressor turned off, the temperature will begin to rise after 30-60 minutes, and complete defrosting can take from 4 to 8 hours.
Is it safe to keep the freezer turned off (at 0) all the time?
Keeping the mechanical thermostat control in the "0" position is safe for electronics, since like the circuit is open. However, if moisture or food remains in the chamber, mold will result. For long-term storage in the switched off state, the chamber must be washed and dried with the door open.