Coolers Aqua Work with a refrigerator function are becoming increasingly popular in offices, small shops and at home. They combine the convenience of a water dispenser with the ability to cool drinks or food to +4...+10°C. However, many users encounter difficulties when turning on the refrigerator for the first time: it is not clear where the activation button is, how to set the desired temperature, or why the device does not cool despite pressing all the keys.
In this article we will examine step-by-step instructions how to turn on the refrigerator in coolers Aqua Work of different series, explain the nuances of setting temperature conditions and We will warn you against typical mistakes that can damage your equipment. We will pay special attention to models with electronic control (Aqua Work AW-100H, AW-150HC) and a mechanical thermostat (Aqua Work Classic Cool).
If your cooler is equipped with a display, the process of turning on the refrigerator compartment will take no more than a minute. In mechanical models, it will take a little more time to adjust the thermostat - but there is nothing there either complicated if you know the sequence of actions. The main thing is not to forget about safety rules: never turn on the cooler immediately after transportation (you need to wait 2-4 hours for the refrigerant to stabilize) and do not place it close to walls or furniture (minimum clearance - 10 cm at the back).
For convenience, we have divided the material into blocks: from basic switching on to solving common problems. If your cooler model is not mentioned in the article, check its exact name in the device passport or on the sticker on the back. Many functions are universal, but the location of the buttons may vary.
1. Preparing the Aqua Work cooler for the first time.
Before that. how to turn on the refrigerator, you need to properly install and prepare the cooler. This applies to both new devices and those that have not been used for a long time.
First, unpack the cooler check the package: the box should contain a power cord, instructions (sometimes in several languages), sometimes a key to lock the buttons. Make sure that there are no visible damages on the case: dents, cracks or marks. corrosion. Inspect especially carefully rear grille the condenser and fan are located there, which can easily be damaged during careless transportation.
Secondly, place the cooler on a flat, stable surface. The ideal option is a special stand or tabletop that can support the weight of the filled device (up to 30–40 kg). Avoid places with direct sunlight, near radiators or other heat sources. The optimal room temperature for the cooler to work is +16...+32°C.
The third step. — connection to the power supply. Use only the original plug and cord included in the kit. If the socket is far away, do not extend the wire yourself - it is better to use a surge protector with grounding. Important: the voltage in the network must correspond to that indicated on the cooler nameplate (usually 220–240 V, 50 Hzit is recommended to connect the cooler through). stabilizer.
- 🔌 Check the voltage in the socket tester - it should not deviate from 220 V by more than 10%.
- ⏳ Let the cooler “settle” after delivery: at least 2 hours in a vertical position (to stabilize the oil in the compressor).
- 🧼 Wipe the internal surfaces the refrigerator compartment with a weak solution of soda (1 tablespoon per 1 liter of water) before the first use.
- 🚫 Do not plug in the coolerIf it has been turned over or tilted more than 45°, wait 4-6 hours.
⚠️ Attention: If the cooler Aqua Work stored at a temperature below +5°C (for example, in an unheated warehouse), before turning it on, keep it in a warm room for at least 12 hours. The refrigerant in such conditions may condense, which will lead to compressor failure.
2 How to turn on the refrigerator: instructions for models with electronic. control
Modern coolers Aqua Work series AW-100H, AW-150HC, AW-200Pro are equipped with a digital display and touch or mechanical buttons. The refrigeration chamber is turned on through the main menu.
Action algorithm:
- Connect cooler to the network and press the main power button (usually indicated
Poweror the ⏻ symbol). The backlight should light up on the display. - Find the button with the image of a snowflake ❄️ or the inscription
Cooling/FridgeIn some models it is combined with the temperature regulator. - Hold the button for 2-3 seconds until the active cooling indicator appears on the screen (for example, a flashing snowflake or temperature number).
- Adjust the target temperature using the buttons
+/–(usual range: +4...+10°C).
In coolers with two-zone cooling (for example Aqua Work AW-180DZ) there may be two separate buttons: one for the upper chamber (for bottles), the other for the lower chamber (for cans or products). In this case, the settings will have to be carried out for each zone separately.
If after pressing the button Cooling nothing happens:
- 🔋 Check if the cooler is connected to the outlet (the power indicator should be on).
- ⏱️ Wait 5-10 minutes - the compressor needs time to start.
- 🔄 Try removing plug from the socket for 30 seconds and reconnect (error reset).
The cooler is connected to the network (Power indicator is on)
Room temperature +16...+32°C
The cooler stood vertically for at least 2 hours
The refrigerator door is closed tightly
-->
Note for models with. display: If an error appears on the screen E1, E2 or E3, this may indicate a problem with the temperature sensor, compressor or fan. In this case do not try to turn on the cooling again - disconnect the cooler from the network and contact the service center.
3. Turning on the refrigerator in mechanical models (without display)
Coolers Aqua Work with mechanical control (Classic Cool, AW-80M) do not have an electronic display. Instead, it is used rotary thermostat, usually located on the rear panel or inside the refrigerator compartment.
To turn on the cooling:
- Connect the cooler to the network and make sure it is working (indicators on the water dispensing panel are lit).
- Find the temperature regulator - this is a round switch with marks from
MIN(or0) toMAX(or7). - Turn the regulator clockwise to 1-2 divisions from the position
OFF(usually a click). - Close the chamber door and wait 15-20 minutes - the compressor should start (you will hear a slight hum).
In mechanical models no accurate temperature indication, so be guided by the following rules:
- 🌡️ Position
1–2—low cooling (+8...+10°C, suitable for water). - ❄️ Position
3–5—medium cooling (+4...+7°C, for drinks and some foods). - ⚠️ Position
6–7—maximum cooling (below +4°C, risk of freezing).
If the compressor does not start:
⚠️ Attention: In mechanical coolers Aqua Work may trigger thermal protection of the compressor with frequent switching on/off. If you turned the regulator several times in a row, wait 30 minutes before trying again.
What to do if the regulator does not turn?
If the thermostat is stuck in position OFF, do not use force! This may be caused by:
- Freezing of moisture inside the mechanism (if the cooler was stored in the cold).
- Broken thermostat (replacement required).
Try to gently rock the regulator left and right or wait 1-2 hours at room temperature. If the problem persists, contact service.
4. Setting the optimal temperature: tips and table of modes
The correctly selected temperature in the refrigeration chamber of the cooler Aqua Work affects not only the freshness of the products, but also the service life of the compressor. Too low values lead to freezing, too high - to insufficient cooling.
Recommended modes for different tasks:
| Purpose of use | Recommended temperature | Cooling time to mode | Notes |
|---|---|---|---|
| Drinking water cooling | +8...+10°C | 1–1.5 hours | Minimum compressor load |
| Drinks (juices, soda) | +5...+7°C | 2–3 hours | Ideal for 0.33–0.5 l cans |
| Dairy products, cheeses | +4...+6°C | 3–4 hours | Do not store more than 24 hours |
| Fruits, vegetables | +6...+8°C | 2 hours | High humidity accelerates spoilage |
| Ice cream (short term) | –10...–15°C* | 5–6 hours | Only in models with a freezing function |
*The freezing function is available only in coolers Aqua Work series Freeze or Premium. In standard models, temperatures below +4°C are not recommended.
To save energy:
- 💡 Use the mode
Eco(if available) - it maintains a temperature of +8°C with minimal energy consumption. - 🔄 Do not open the door more than once per 30 minutes - up to 20% of the cold is lost each time.
- ☀️ Keep the cooler away from direct sunlight - this reduces the load on the compressor.
5. Typical errors and why the refrigerator does not turn on
If after all the manipulations the fridge compartment of the cooler Aqua Work does not cool, check the following points:
1. Power problems:
- 🔌 The plug is not tightly inserted into the socket or the contact has oxidized.
- 🔋 The power cord is damaged (frayed, bent).
- ⚡ The lights in the house are turned off or the machine has tripped (check others devices).
2. Compressor malfunctions:
- 🔊 The compressor hums, but does not start - there may be a refrigerant leak or jamming.
- 🌡️ The compressor turns on for 1-2 seconds and turns off - overheating protection is triggered.
- ❄️ Ice forms on the back wall of the chamber - the thermostat or fan is faulty.
3. User errors:
- ⏳ The cooler was turned on immediately after transportation (you need to wait 2-4 hours).
- 🚪 The chamber door is not closed tightly (check the seal).
- ☀️ The room temperature is above +32°C (the compressor is not will cope with the load).
If the cooler makes unusual sounds:
⚠️ Attention: Extraneous noises during compressor operation (knocking, grinding, vibration) may indicate breakage of shock absorbers or entry of foreign objects the fan. Immediately disconnect the device from the network and inspect the rear panel.
To diagnose breakdowns in coolers Aqua Work you can use error codeswhich are displayed (in electronic models):
| Error code | Value | Recommendations |
|---|---|---|
E1 |
Temperature sensor malfunction | Turn off for 10 minutes, then turn on again. If the error remains, service. |
E2 |
Problem with the compressor | Do not turn on the cooling until the problem is resolved. |
E3 |
Fan failure | Check whether the blades are blocked. Clean from dust. |
E4 |
Compressor overheating | Allow the cooler to cool for 1-2 hours. Check the ventilation. |
The refrigerator does not cool, but the water works
The cooler does not turn on at all
An error appears on the display
Strange sounds are heard during operation
Other option
-->
6. fridge care compartment: how to extend its service life
To ensure that the cooler Aqua Work serves for a long time and the refrigerator compartment works efficiently, follow simple rules of care:
1. Regular cleaning:
- 🧽 Wash the internal surfaces of the chamber every 2 weeks warm water with soda or a special product for refrigerators.
- 🧊 Defrost the chamber when ice forms more than 5 mm thick (in models without
No Frost). - 🌬️ Vacuum the rear grille once a month —the accumulation of dust impairs heat transfer.
2. Correct operation:
- 🚫 Do not place hot foods or open liquids in the chamber (this increases humidity).
- 📦 Do not overload the chamber - leave a gap of 2-3 cm between products for air circulation.
- 🔄 If the cooler is not used for more than a week, turn off the refrigerator compartment (turn down the thermostat on
0).
3. Prevention of breakdowns:
- ⚡ Use voltage stabilizerif your network has frequent surges.
- 🔋 Once every six months check door seal —it should not be hard or cracked.
- 🛠️ Once a year, invite a technician to checking the refrigerant and lubricate the compressor.
For models with the function Auto Defrost (automatic defrosting), it is enough to wipe the chamber with a dry cloth once every 3 months. In manual models, defrosting is carried out when ice forms:
Disconnect the cooler from the mains
Take out all the products and shelves
Place a tray to collect water
Leave the door open for 2-3 hours
Wipe the chamber and seal dry
Connect the cooler and turn on cooling
-->
In Aqua Work coolers with the No Frost system, it is strictly forbidden to mechanically remove ice with a knife or other sharp objects - this will damage the evaporator and lead to refrigerant leakage.
7. Comparison of Aqua Work coolers with a refrigerator: which models are better
Not all coolers Aqua Work are equipped with a fridge compartment. If this function is important to you, pay attention to the following series:
| Model | Control type | fridge compartment volume | Minimum temperature | Features |
|---|---|---|---|---|
| Aqua Work AW-100H | Electronic (display) | 20 l | +4°C | Quiet compressor, function Eco |
| Aqua Work AW-150HC | Electronic (sensor) | 25 l | +3°C | Two-zone cooling, Super Cool |
| Aqua Work Classic Cool | Mechanical | 15 l | +5°C | Simple design, low price |
| Aqua Work AW-200Pro | Electronic (Wi-Fi) | 30 l | –5°C | Control from a smartphone No Frost |
When choosing a model, pay attention to:
- 📏 Chamber volume —for an office 20–25 l is suitable, for home you can take a compact one 15 l.
- ❄️ Minimum temperature — if you need freezing, look for models marked
Freeze. - 🔊 Noise level —for a bedroom or small room, choose coolers with a compressor no louder than 40 dB.
- 💰 Energy consumption - class models
A+save up to 30% energy.
If you plan to use a cooler for storing perishable products (dairy products, meat), give preference to models with antibacterial coating chambers (for example, Aqua Work AW-180Biothey slow down the growth of mold and bacteria.
FAQ: Frequently asked questions about refrigerators in Aqua Work coolers
❓ Is it possible to use the refrigerator compartment of a cooler for long-term storage of food?
No, coolers Aqua Work are not intended for long-term storage of perishable products (more than 24 hours). They maintain a temperature of +4...+10°C, but do not have hermetically sealed insulation, like household refrigerators. For meat, fish or dairy products, it is better to use specialized equipment.
❓ Why does the refrigerator compartment work, but does not cool to the set temperature?
There are several reasons:
- 🔥 The room is too hot (above +30°C) - the compressor cannot cope with the load.
- 🚪 The chamber door does not close tightly (check the seal).
- ❄️ Ice has built up on the back wall (needs defrosting).
- 💨 The fan or condenser is clogged (needs cleaning).
Check these points and repeat the temperature setting.
❓ How often do you need to defrost the refrigerator compartment?
The frequency of defrosting depends on the model:
- 🌨️ In coolers without No Frost — once every 1–2 months or when ice builds up to a thickness of 5 mm.
- ❄️ In models with No Frost — once every 6 months (wiping is enough).
After defrosting, do not turn on the cooler immediately - let it stand for 30 minutes with the door open.
❓ Is it possible to turn off the refrigerator at night?
Yes, if you do not store food in it. To save energy, you can turn off the cooling for 6–8 hours (for example, at night), but not more than once a day. In mechanical models, simply turn the thermostat to 0, in electronic models - press Cooling until the indicator turns off.
❓ What to do if the display flashes error E1?
Error E1 indicates a problem with the temperature sensor. Try:
- Disconnect the cooler from the network for 10 minutes, then turn it on again.
- Check that the chamber door is tightly closed.
- If the error persists, contact the service center (the sensor or control board may be faulty).