How to make one from two refrigerators: 5 working methods with instructions

Combining two refrigerators into a single system is a task that arises for owners cafes, small shops or households with limited space. Most often, this is true when one unit fails and the second one is worn out, or when it is necessary to create zones with different temperature conditions (for example, for meat and vegetables). But before you take up the tools, it is important to understand: not all refrigerators can be physically combined, and some methods require serious modifications to the electrical and thermal insulation.

In this article we will analyze 5 proven methods - from simple connection to one power source to full integration of cameras with a common compressor. You will learn which models Samsung, Indesit or Atlant are best modified, how to avoid short circuits when connected in parallel, and why combining freezer and refrigerator compartments can save up to 30% of electricity. We will also provide cost calculation alterations and a table of brand compatibility.

⚠️ Critical warning: Any manipulations with freon circuits or electricity require a refrigeration certificate. Incorrect connection of the pipes can lead to leakage of freon R-134a or R-600a (explosive at concentrations above 31 g/m³) or damage to the compressor. If you are not confident in your skills, contact a specialist certified in FNP No. 538 (rules for working with refrigerants).

1. Method No. 1: Parallel connection to one compressor

This is the most complex, but also the most effective method that allows combine two chambers into a single cooling system. Operating principle: one compressor circulates freon through two circuits, regulating the temperature in each zone separately. This approach is used in industrial refrigerators, but it can be adapted for household models only if three conditions are met:

✅ Both refrigerators must be of the same brand and approximately the same year of manufacture (for example, LG GA-B489 i LG GA-B489S). Different brands use incompatible refrigerants and oil for compressors

✅ The total volume of the chambers should not exceed 400 liters - otherwise the compressor will wear out.

✅ One of the refrigerators must have a working compressor with a power reserve (see parameter BTU/h in the passport).

For implementation you will need:

  • 🔧 Median tubes with a diameter of 6–8 mm (the length depends on the distance between the refrigerators).
  • 🔥 Torch for soldering with solder (for example, Castolin 192 for copper tubes).
  • 📏 Manometer to check the pressure in the system (norm: 0.5–1.5 bar at rest).
  • 🛠️ Vacuum pump to remove moisture before charging with freon.

Drain freon from both refrigerators (only certified equipment)|

Check the integrity of the seals on the doors|

Install check valves on each circuit|

Connect a pressure gauge to the service port|

Solder the tubes using argon welding (not soldering iron!)

-->

⚠️ Attention: If freon was used in one of the refrigerators R-12 (banned since 2020), it cannot be mixed with modern refrigerants (R-134a, R-600a). A complete oil change in the compressor and flushing of the system will be required.

2. Method No. 2: Uniting through a common thermostat

A simpler option is to connect both refrigerators to one thermostat, which will control their operation synchronously. This method is suitable if:

- You do not need different temperatures in the chambers (for example, both compartments will work as freezers).

- Refrigerators are nearby, and you can stretch the control cable between them.

For implementation buy programmable thermostat (for example, STC-1000 or Xiaomi Mijia Temperature & Humidity Monitor) and connect it according to the scheme:

```html

ElementConnectionNote
ThermostatTerminals COM i NOUse a 10A relay
1st refrigeratorWire from the compressor to LPolarity is not important
2nd refrigeratorParallel to the first through the terminal blockMax. load: 2200 W
Temperature sensorPlace in the main chamberIsolate from direct cold

```

⚠️ Attention: If the total power of the compressors exceeds 2 kW, the thermostat may overheat. In this case, add intermediate relay (for example, Finder 40.52).

Two household ones (for example, Atlant and Biryusa)|

Household + industrial|

Two freezers|

Another option-->

3. Method No. 3: Creating a single body with thermal insulation

If the refrigerators are back to back, you can combine them physicallyby removing partitions and increasing thermal insulation. This method is popular among owners of small shops where they need to increase the useful volume without purchasing new equipment.

Step-by-step instructions:

  1. Disconnect both refrigerators from the network for 24 hours (for defrosting and evaporation freon).
  2. Remove the doors and internal shelves. In models Samsung RB or Liebherr CN the shelves are fastened with latches - they can be removed without tools.
  3. Cut out the partition between the chambers with a grinder (if the refrigerators are close together, use a disc). metal 1.6 mm thick.
  4. Install an additional layer of insulation (polyurethane foam or Penofol 20 mm thick) at the joints.
  5. Secure a new common door or leave two separate ones, but add magnetic seals.

💡 Tip: To seal the seams, use silicone sealant Dow Corning 7091 —it can withstand temperatures from −60°C to +180°C and does not crack over time.

What to do if, after combining, the refrigerator does not cool?

If, after physical combining, the temperature in the chambers does not drop below +10°C, check:

1) Integrity of the freon circuit (when cutting the housing, the tubes could be damaged).

2) Fan operation (in models with No Frost it can be blocked by dust).

3) Refrigerant leakage - listen to the hissing sound near compressor.

If the problem is a leak, refilling with freon will be required (cost: from 3500 ₽).

4. Method No. 4: Using one refrigerator as a freezer

If you do not need to physically combine the chambers, you can repurpose one refrigerator as a freezerand leave the second for cooling. This is true for models with a system Full No Frost, where the temperature is controlled electronically.

How to set up:

  • 🔄 Set the temperature in the first refrigerator −18°C ("Super Freeze" mode).
  • 🌡️ Set the temperature in the second refrigerator +4°C (optimal for vegetables and dairy products).
  • 🔌 Connect both units via smart socket (for example, TP-Link HS100) to control the power remotely.

⚠️ Attention: In refrigerators with a drip system (Indesit DF 4180, Bosch KGN39XL20R) during prolonged operation in freezer mode, ice may form on the back wall. Solution: defrost the unit every 2 months.

5. Method No. 5: Connecting to one outlet with a timer

The most budget option is alternate switching on refrigerators through a rail with a timer. This does not combine them into one system, but allows:

- Save energy (one refrigerator works while the second one is “resting”).

- Extend the life of compressors (reduces the load on the network).

Connection diagram:

  1. Buy mechanical timer (for example, Feron TM50) or a smart socket with a schedule function.
  2. Set up graph: Refrigerator A works for 2 hours, then Refrigerator B turns off and turns on.
  3. Set the delay between switching to 10-15 minutes (to avoid power surges).

📊 Calculation of savings:

At a tariff of 5 ₽/kWh and power compressors of 150 W each, alternating operation will save up to 400 ₽ per month compared to simultaneous switching on.

Comparison of methods: pros and cons

```html

MethodComplexityCost, ₽Energy consumptionSuitable for
General compressor⭐⭐⭐⭐⭐8000–15000↓ by 30%Experienced masters
Common thermostat⭐⭐⭐2000–4000↓ by 15%Household refrigerators
Single body⭐⭐⭐⭐5000–10000→ no changesShops, cafes
Repurposing⭐⭐0–1500↓ by 10%Home use
Timer in socket500–2000↓ by 20%Temporary solution

```

Common errors and how to avoid them

🔴 Error 1: Connecting refrigerators with different refrigerants to the same circuit.

Consequences: Reaction between R-134a and R-600a leads to the formation of acids that corrode aluminum tubes.

Solution: Rinse the system freon R-141b and fill with universal freon R-404A (suitable for 90% of household models).

🔴 Error 2: Use of a conventional extension cord for parallel connection.

Consequences: Overheating of contacts and fire (extension cords are not designed for starting currents of compressors).

Solution: Connect via power socket with grounding (for example, Legrand Valena) or install a separate line with a circuit breaker on 16A.

🔴 Error 3: Combining refrigerators without leveling.

Consequences: Compressor vibration is transmitted to the second housing, which leads to premature wear of the bearings.

Solution: Use shock-absorbing pads (for example, VibraStop) and set both refrigerators to the building level.

Common compressor (have experience working with freon)|

Common thermostat (simple solution)|

Single housing (needs a large volume)|

None - too risky-->

FAQ: Answers to frequently asked questions

Is it possible to combine a refrigerator No Frost and drip?

Technically yes, but there is nuances:

- In a drip refrigerator (Atlant MXM 1705), moisture condenses on the back wall, and in No Frost (Samsung RB37J5240it is evaporated by a fan. When combined, moisture can accumulate in the freezer, forming ice.

- Solution: Install additional desiccant (silica gel) or organize supply and exhaust ventilation.

How much will a turnkey refurbishment cost from a master?

Prices in 2026 (Moscow region):

  • 🔧 Consolidation of compressors: 12 000–20 000 ₽ (including freon and soldering).
  • 🔌 Connection to a common thermostat: 3 500–6 000 ₽.
  • 🏗️ Creation of a single housing: 8 000–15 000 ₽ (including insulation).

⚠️ Prices may vary depending on the model and region. Check with local service centers.

Which freon is best to use for refilling after combining?

The choice of refrigerant depends on the type of compressor:

  • For older models (before 2010 year): R-134a (but requires an oil change for POE).
  • For new ones (after 2015): R-600a (isobutane) - more environmentally friendly, but explosive.
  • Universal option: R-404A (suitable for 80% of household refrigerators).

💡 Important: After refueling, check the system for leaks. data-i="285">Yes, but with reservations: electronic leak detector (For example, Inficon D-Tek Select).

Is it possible to combine a refrigerator and freezer display?

Yes, but with reservations:

- Freezer display cases (Pozis RF-140) are designed for temperature −22°C, and household refrigerators are designed for +4°C. It will not be possible to combine them into one circuit.

- Solution: Use double-circuit system with separate evaporators or connect the display case as an independent zone through a common thermostat.

What to do if, after combining, the refrigerator begins to make noise?

Causes and solutions:

  • 🔊 Compressor vibration: Install rubber shock absorbers under the housing.
  • 💨 Fan noise: B models No Frost clean the blades of dust.
  • 🔥 Transformer hum: Check the voltage in the network (there should be 220V ± 10%).

If the noise does not disappear - probable compressor malfunction (diagnostics required).